25 Nov Metal Studs Explained: Sizes, Gauges, Types and Uses
Metal studs are cold-formed galvanized steel members that form the vertical framework of interior walls, ceilings, and many exterior walls. Every Denver commercial build-out, tenant improvement, and basement finish eventually asks the same questions. What size do I need? Which gauge is right? Can the wall carry load? Will drywall finish look right over it? This guide answers each one with the specs and decision rules we use on real jobs. If you want the process side of the work, see our steel stud framing service in Denver.
What Are Metal Studs Made Of and How Are They Shaped?
A metal stud is a C-shaped channel rolled from thin galvanized steel sheet. The shape gives a light member real stiffness, and the coating protects the steel from rust inside wall cavities.
What do the flange, web, and return lip do?
The web is the flat back of the channel, and it sets the stud depth. Two flanges extend from the web at right angles. Drywall screws bite into the flange, so flange width controls how much landing area the board gets. Most drywall studs have a flange of about 1-1/4 inches to 1-5/8 inches. Many studs add a small return lip on each flange to stiffen it. Punched holes in the web, called knockouts, let electricians and plumbers pass conduit and pipe straight through the wall.
- Web: sets the stud depth, such as 3-5/8 inches
- Flange: holds the drywall screws, roughly 1-1/4 to 1-5/8 inches wide
- Knockouts: pre-punched web holes for wiring and small pipe
- Return lip: stiffens the flange edge on many profiles
Why is galvanized steel the standard coating?
Galvanized steel carries a zinc layer that sacrifices itself before the base steel corrodes. Zinc coating matters most in basements, exterior walls, and humid spaces. Heavier coatings cost more but suit exposed or damp conditions. For ordinary dry interior partitions, standard galvanizing performs well for the life of the building.
Need Steel Stud Framing for a Denver Project?
Steel Bridge Construction frames interior partitions, demising walls, and fire-rated assemblies for commercial projects across the Denver metro.
Get a Free EstimateWhat Sizes Do Metal Studs Come In?
Metal stud sizes are named by web depth, and the common sizes run from 1-5/8 inches to 6 inches. Depth drives wall thickness, insulation space, and how tall the wall can safely run.
What are the standard metal stud depths?
Metal stud depth is the web dimension, and these sizes cover most Denver projects:
- 1-5/8 inch: furring, short walls, and shaft-wall liners
- 2-1/2 inch: tight partitions where space matters
- 3-5/8 inch: the default for commercial interior walls
- 4 inch: a middle option for added height or plumbing space
- 6 inch: tall walls, deep plumbing chases, and exterior framing
A 3-5/8 inch stud with two layers of 5/8 inch drywall on each side gives a wall about 6 inches thick. Our drywall thickness guide explains how board choice changes that total.
What are standard metal stud lengths?
Metal stud lengths are stocked at 8, 9, 10, 12, and 14 feet, with longer pieces available by special order. Most suppliers sell 10 foot studs as the workhorse length. Studs are cut to fit on site, so a 9 foot ceiling wall is usually framed from a 10 foot piece. Ordering the right length saves waste, because every offcut is money left on the floor.
What Do 25, 20, 18, and 16 Gauge Mean for Metal Studs?
Metal stud gauge describes steel thickness, and a lower gauge number means thicker, stronger steel. The jump between gauges is large, so the choice affects strength, cost, and the tools needed to install them.
How do the gauges compare?
The table below lists approximate thickness and typical use for each common gauge. Thickness is shown in mils, where one mil equals 0.001 inch. Exact values vary by manufacturer and by drywall versus structural product lines.
| Gauge | Approx. Thickness | Typical Use | Structural? |
|---|---|---|---|
| 25 gauge | about 18 mil | Standard interior partitions, low walls | No |
| 22 gauge | about 27 mil | Taller partitions, heavier finishes | Usually no |
| 20 gauge | about 30 to 33 mil | High partitions, shaft walls, light structural | Depends on product |
| 18 gauge | about 43 mil | Load-bearing walls, exterior framing | Yes |
| 16 gauge | about 54 mil | Heavier load-bearing walls, headers, tall exterior walls | Yes |
Is 25 gauge or 20 gauge better for a partition wall?
A 25 gauge stud suits most standard partitions up to a modest height, and a 20 gauge stud suits taller or more demanding walls. Choose 20 gauge when walls carry heavy tile, cabinets, or grab bars, or when the wall runs high. Choose 25 gauge for ordinary offices and basement dividers. The engineer or the architect’s wall-type schedule makes the final call.
What Is the Difference Between Structural and Non-Structural Metal Studs?
Structural metal studs carry building loads, while non-structural studs only hold up drywall and resist light lateral pressure. Mixing them up is the costliest mistake on a framing job.
When do you need load-bearing studs?
Load-bearing studs are required wherever a wall supports a floor, a roof, or another wall above. These studs are typically 18 gauge or 16 gauge, and sometimes heavier. They come with engineered spacing, bracing, and connection details. A non-load-bearing partition, by contrast, carries only its own weight plus the finishes. Our rule: never assume a wall is non-structural from looks alone. Confirm it against the structural drawings or have an engineer review it before any stud is cut.
How do you decide between the two?
- Wall supports floor, roof, or wall above: structural, usually 18 or 16 gauge
- Wall only divides rooms: non-structural, usually 25 or 20 gauge
- Wall is exterior and wind-loaded: engineered stud, size and gauge per design
- Wall is unknown: treat as structural until verified
If you are comparing materials for a structural wall, our guide to steel studs versus wood studs covers the tradeoffs in detail.
What Is Stud Track and How Does It Work?
Stud track is the U-shaped channel that caps the top and bottom of a metal stud wall. Track anchors the wall to the floor and ceiling, and the studs slide into it.
How does track differ from a stud?
Track has a solid web and short legs, usually 1-1/4 inches, with no return lip and no punched holes. Track depth matches the stud depth, so a 3-5/8 inch stud needs 3-5/8 inch track. The legs of the track are slightly wider inside than the stud flanges, which lets the stud fit snugly. Installers fasten the studs to the track with pan-head screws or crimp them, depending on the job.
How is track fastened and spaced?
Track is fastened to concrete with powder-actuated pins or concrete screws, and to wood or steel decking with screws. Fastener spacing is commonly about 24 inches on center, closer near ends and corners. Studs sit at 16 inches or 24 inches on center. Sixteen inches suits heavier finishes and tile. Twenty-four inches saves material on lighter walls. In Denver high-rise and office work, deflection track at the ceiling is common. A slotted top track lets the structure above move without cracking the drywall.
Will Joint Compound Stick to Metal?
Joint compound does not bond well to bare metal studs, and it is not supposed to. The compound goes over drywall tape and board paper, not onto the steel framing.
How do drywall screws attach to metal studs?
Drywall attaches to metal studs with fine-thread screws that bite through the flange. The screw head sits just below the paper surface. Compound then fills that dimple. Compound bonds to the paper face of the board, so the metal behind it never matters. Use fine-thread screws for 25 gauge and 20 gauge studs. Self-drilling screws handle 18 gauge and heavier steel. Our article on Level 5 drywall finish shows how the compound layers build up over the board.
What about corner bead and exposed metal?
Metal corner bead and trim sit on the board edge, and compound does cover them. Setting-type compound, the powder you mix, grips galvanized bead better than premixed all-purpose mud. Prime any bare galvanized surface before painting, because paint also struggles to hold on raw zinc. Common failures include cracked compound over bare track and peeling paint on unprimed bead. Both come from skipping the right base coat, not from the stud itself.
How Do Metal Studs Fit Into Fire-Rated Assemblies?
Metal studs form the frame of most fire-rated assemblies, but the stud alone does not carry the rating. The rating comes from the tested combination of studs, drywall type, fasteners, and joint treatment.
What makes up a fire-rated wall?
A fire-rated assembly is a tested wall design, such as a one-hour or two-hour partition. Typical one-hour designs use 5/8 inch Type X gypsum board over metal studs. The listing specifies stud size, gauge, spacing, board layers, screw spacing, and insulation. Changing any item can void the listed rating. Penetrations also need approved firestopping, and the fire marshal or building inspector checks the work.
How should you plan around rated walls?
- Stud gauge: follow the listed assembly, not a substitute
- Board: Type X, often 5/8 inch, in the specified layers
- Wall height: run rated walls to the deck above, not just the ceiling grid
- Penetrations: use listed firestop systems for pipes and cables
Plan the rated walls first, because they control the framing schedule and inspection timing.
How Much Do Metal Studs Cost in Denver in 2026?
Metal stud framing in Denver typically costs about $3 to $8 per square foot of wall surface installed, depending on gauge, height, and job size. These are 2026 Denver-metro estimates, not quotes. Final pricing depends on drawings and site conditions.
What do the materials and installed wall cost?
| Item | Estimated Cost (Denver Metro, 2026) |
|---|---|
| 25 gauge, 3-5/8 inch, 10 ft stud (material only) | about $5 to $9 each |
| 20 gauge, 3-5/8 inch, 10 ft stud (material only) | about $8 to $14 each |
| 18 gauge structural stud, 10 ft (material only) | about $12 to $20 each |
| Track, 10 ft section (material only) | about $4 to $10 each |
| Non-load-bearing partition, framing only, installed | about $3 to $6 per sq ft of wall |
| Load-bearing or engineered wall, framing only, installed | about $5 to $8+ per sq ft of wall |
What drives the price up or down?
- Gauge: heavier steel costs more per piece and takes longer to fasten
- Wall height: tall walls need heavier studs and more bracing
- Layout: many short walls and openings raise labor per square foot
- Fire rating: added layers and firestopping raise total wall cost
- Access: occupied buildings and off-hours work add labor cost
For how framing fits into the larger budget, see our commercial remodel cost per square foot guide.
How Do You Choose the Right Metal Stud for Your Project?
Choosing the right metal stud starts with the wall’s job, then height, then finish. A simple sequence prevents most spec errors.
What is a simple selection process?
- Decide if the wall is load-bearing, non-load-bearing, or fire-rated.
- Check the wall height and pick the stud depth that spans it.
- Match the gauge to the load, finish weight, and any engineer’s note.
- Set stud spacing at 16 or 24 inches on center based on the finish.
- Pair the stud with matching track and the specified drywall.
What mistakes do contractors see most often?
Under-specified gauge is the most common error. A 25 gauge stud on a tall wall flexes, and the drywall seams crack later. The second error is mismatched track and stud depth. The third is skipping blocking where cabinets, TVs, or grab bars will mount. Add blocking before the board goes up, because finding studs later costs more than planning for them. Steel Bridge Construction can review your drawings, confirm the stud schedule, and frame the job start to finish. Call (720) 930-5728 or visit us at 7535 E Hampden Ave, Suite 400, Denver, CO 80231.
Ready to Get Your Framing Scoped?
Send us your plans or floor layout and we will confirm stud gauge, spacing, and scheduling for your project.
Get a Free EstimateFrequently Asked Questions
What is the most common metal stud size?
The most common metal stud size is 3-5/8 inches deep, usually in 25 gauge or 20 gauge. Contractors use it for most commercial interior partitions because it balances wall thickness, insulation space, and cost. Taller walls or plumbing chases often step up to 4 inch or 6 inch studs.
Is 20 gauge or 25 gauge metal stud stronger?
A 20 gauge metal stud is stronger than a 25 gauge stud because the steel is thicker. The 20 gauge product handles taller walls and heavier loads such as tile or cabinets. Standard low partitions usually perform fine with 25 gauge and cost less.
Can metal studs be used for load-bearing walls?
Metal studs can be used for load-bearing walls when they are structural studs, typically 18 gauge or 16 gauge, and the design is engineered. Standard 25 gauge drywall studs are not load-bearing. Always confirm the stud size, spacing, and bracing against the structural drawings first.
What is the difference between a metal stud and metal track?
A metal stud is the vertical C-shaped member, while metal track is the U-shaped channel at the floor and ceiling. Track has no return lips or knockouts. Studs slide into the track and are fastened to it, forming the wall frame.
How far apart should metal studs be spaced?
Metal studs are commonly spaced 16 or 24 inches on center. Sixteen inches suits heavier finishes like tile and gives a stiffer wall. Twenty-four inches saves material on lighter partitions. Fire-rated and structural walls must follow the spacing listed in their design.
Do metal studs need to be primed before drywall mud?
Metal studs do not need primer before drywall, because the board covers them. Joint compound is applied over tape and paper, not the steel. Exposed galvanized items, such as corner bead or trim, should be primed before painting to prevent peeling.